Test Method: EN-14112, ASTM D6751, ISO 6886
Oxidation stability of FAME (fatty acid methyl esters) for biodiesel
•  Multiple models available to fit any budget
• Conforms to EN-14112 test method for B100 biodiesel
• Measures oxidation stability of FAME
(fatty acid methyl esters)
• Soon to be a requirement of ASTM D6751 specifications
• Automated operation
• Windows PC controlled
• Operating temperature from 40° to 150°C
• Temperature stability of ±0.2°C
Click for automated testing cold filter plugging point (CFPP)
Click for manual testing cold filter plugging point (CFPP)
Click for cloud point testing apparatus
Click for kinematic viscosity baths
Click for copper corrosion testing apparatus
Click for additional oxidation stability test apparatus

Model 321 series of oxidation stability baths conform to the requirements of EN-14122 test method, soon to be incorporated in ASTM D6751 specifications for B100 fatty acid methyl esters (FAME) for biodiesel blending.

Models 321 series employ multiple aluminum blocks configured to fit the specified test tube holding 3.0 gm of FAME (fatty acid methyl esters). When the sample reaches test temperature of 110°C filtered, dry air is sparged at 10 ± 1L/hr. to each test specimen.

The volatiles generated (organic acids) from this oxidation process are collected in a receiver of distilled or deionized water. The increase of acidity in the receiver is measured with time with an integral conductivity measuring device. The oxidation induction period is automatically calculated based on the break in the rate of increase (second derivative) of conductivity in the receiver.

Each position’s receiver has cap with an integral conductivity probe reporting data to the PC.

Model 317-8 is an economical liquid bath with a range of ambient to 150°C with 8 test positions.

Available Models
Model No.
No. of
Test Positions
Description
321-2
2
Economical model, single block bath, supplied with operating software, glassware, connecting tubing, two conductivity probes, optional air filter/dryer and pump, PC not included.
321-4
4
Single block bath with 4 test positions, supplied with operating software, glassware, connecting tubing, 4 conductivity probes, optional air filter/dryer and pump, PC not included.
321-8
8
Fully equipped with air pump, filter, dryer, laptop PC, operating software, 2 independent aluminum heated blocks each with 4 test positions, 8 conductivity probes, all glassware and connecting tubing (for 8 positions).
321-16
16
Fully equipped with air pump, filter, dryer, laptop PC, operating software, 4 independent aluminum blocks each with 4 test positions, 16 conductivity probes, all glassware and connecting tubing (for 16 positions).
317-8
8
Economical liquid bath with flow meter, supplied with operating software, glassware, connecting tubing, conductivity probes, optional air filter/dryer and air pump. PC not included.

Accessories and Options
Part No.
Description
EN-10
Oxidation reaction vessel
EN-11
Sealing cap for reaction vessel with air inlet tube, and outlet tubing
EN-12
Measuring vessel
EN-13
Cap for measuring vessel with probe, inlet tube and vent
EN-14
Certified temperature probe with digital display
EN-15
Portable air pump with filter and molecular sieve dryer
EN-16
Molecular sieve dryer with filter assembly
EN-17
Silicone connecting hose, 50 ft.
EN-18
Pipette, 50 mL
EN-19
Desiccator
EN-20
Drying oven to 150°C
EN-21
Optional float in tube flow meter with precision control valve
EN-22
Pressurized house air setup for converting to instrument air

Lawler Manufacturing Corporation © 2005