Five models are available conforming to ASTM D2983 Test Method for Low Temperature Viscosity of Automotive Fluids Measured by Brookfield Viscometer. Each model is equipped with turntable rotating at 4 RPM. Ample storage is provided inside the cold chambers for pre- cooling the insulated cell carriers. A digital, indicating controller with resolution of 0.1°C, maintains set temperature to ±0.1°C.
Model BV-70 has an 28 cm (11 inch) square, multipane, insulated window with fluorescent light for observation of the interior, with 28 sample capacity. A video chart recorder (option -V) to track possible temperature upsets, and a digital sample temperature display (option -D) are available for Model BV-70.
Model BV-40 is a smaller, floor space saving, compact unit, with 12 sample capacity. No viewing window, but with digital sample temperature display.
Model BV-40-2 has two air test chambers. The twin air chambers are independently temperature controlled. The two chambers allow simultaneous conditioning of samples at the same or different temperatures for quicker data collection then with only one apparatus. Each chamber has a turn table with 6 sample capacity each.
Model BV-20 is a compact, bench top unit with 6 sample capacity with digital sample temperature display. It is designed for those laboratories with a very light sample load and limited space and budget.
Model BV-20G is the floor model version of Model BV-20.
|
BV-20
|
1
|
6
|
-50ºC
|
Bench Model
|
38x27x26
(95x68x65)
|
300/28
|
|
BV-20G
|
1
|
6
|
-50ºC
|
Floor Model
|
20x26x43
51x66x109
|
300/28
|
|
BV-40
|
1
|
12
|
-50ºC
|
Floor Model
|
28x36x43
(71x91x109)
|
440/32
|
|
BV-40-2
|
2
|
6 + 6
|
-50ºC
|
Floor Model
|
36x28x43
(91x71x109)
|
445/32
|
|
BV-70
|
1
|
28
|
-60ºC
|
Floor Model
Viewing Window
|
37x33x46
(83x94x117)
|
500/53
|
|
|
|
Accessores for Single Bath |
|
1
|
Brookfield Viscometer (one required, second optional): Model LVDV-II+ Digital Viscometer
(115V or 230V, 60Hz) |
|
*
|
DV Gather+ Data Capture Software for Model LVDV-II+ Viscometer |
|
*
|
Brookfield Viscometer Re-calibration and Re-certiication to ISO9000 |
|
1
|
LB-VR Mounting assembly (included if viscometer is purchased from Lawler)
|
|
10
|
#4B2 Insulated Spindles (20 pcs for max capacity on LB-76-2 series) |
|
12
|
LB-F Test Cells (24 pcs for max capacity on LB-76-2 series) |
|
10
|
LB-Z Test Stoppers (20 pcs for max capacity on LB-76-2 series) |
|
10
|
LB-K Cell Covers (20 pcs for max capacity on LB-76-2 series) |
|
3
|
N27B Reference Fluid -40º to -18º C (37,000 cP @ -40º C) |
|
3
|
N115B Reference Fluid -29º to -7º C (12,000 cP @ -12º C) |
|
3
|
N14B Reference Fluid 17,000 cP @ -40º C |
|
*
|
N120B Reference Fluid 150,000 cP @ -40º C |
|
*
|
N480B Reference Fluid 150,000 cP @ -26º C |
|
*
|
N60B Reference Fluid 150,000 cP @ -55º C |
|
*
|
N1400B Reference Fluid 150,000 cP @ -12º C |
|
Specifications are subject to change without notice. |
|
|
|
 |
|