Fully automated instruments for the measurement of cold filter plugging point (CFPP). Conforms to ASTM D6371, IP309, EN-116 and related test methods. Each test position of the instrument consists of the specified test tube with two spacers, pipette, brass filter holder assembly, metal test jacket.
Vacuum control provided by a two jar system exactly as specified by the test method, or an automated electronic vacuum control system, or by any existing system currently used for the manual testing.
When the test sample cools to the preselected temperature, the vacuum is automatically applied to the burette, the timer is started, and the vacuum is broken to release the sample back into the test tube in the cooling jacket. The test is repeated when the sample cools by 1°C. At the temperature at which the sample fails to fill (or empty) the pipette in 60 seconds the test is stopped, and the temperature is displayed as the result. All operations are controlled via a touch panel for display of sample temperature, bath temperature, and the CFPP result temperature.
Available in various combinations of test heads in a single unit for CFPP, Cloud, Pour, and Freeze Points. All positions are independent of each other.
Model DR4 series of chillers for cooling the automated analyzers uses the Lawler developed concept of direct refrigeration. The test cup (metal jacket) for cloud point, pour point, or CFPP is directly cooled by the refrigerant, thus replacing the middle step of first cooling the flammable alcohol and then pumping the cold alcohol to the test jacket. Offers the additional advantage of rapid cool down to test temperature within minutes versus hours with bulky floor model cryostat models. The automated analyzer is mounted on the same cabinet as the refrigeration system, thus saving valuable laboratory space. DR4 series coolers are available in 1 or 2 test positions with lowest temperature of either -34° or -70°C.
Model OL series are designed to work with an external alcohol chiller, either your own or supplied by Lawler. OL series units are available in 1, 2, 3, or 4 position units. Lawler offers two recirculating chiller models (MRCC-80 and MRCC-5) for use in conjunction with the OL analyzer.
Model MRCC-80 is a high capacity cryostat able to cool up to three Model OL series analyzer positions.
Its lowest operating temperature is -70°C.
Model MRCC-5 is a very high capacity cryostat able to cool up to six Model OL series analyzer positions.
Its lowest operating temperature is -70°C. This model has a 5 year guarantee against compressor failure.
Integrated Automated Analyzer with Direct Refrigeration (Dry Bath) Unit.
|
DR4-10
|
1 Cloud Point automated test position |
|
DR4-11
|
2 Cloud Point automated test positions |
|
DR4-12
|
1 Cloud Point + 1 Pour Point automated test positions |
|
DR4-14
|
1 Cloud Point + 1 CFPP automated test positions |
|
DR4-15
|
1 Cloud Point + 1 Freeze Point automated test positions |
|
DR4-20
|
1 Pour Point automated test position |
|
DR4-22
|
2 Pour Point automated test positions |
|
DR4-24
|
1 Pour Point + 1 CFPP automated test positions |
|
DR4-25
|
1 Pour Point + 1 Freeze Point automated test positions |
|
DR4-40
|
1 CFPP automated test position |
|
DR4-44
|
2 CFPP automated test positions |
|
DR4-45
|
1 CFPP + 1 Freeze Point automated test positions |
|
DR4-50
|
1 Freeze Point automated test position |
|
DR4-55
|
2 Freeze Point automated test positions |
|
|
I
Automated Analyzer with External Chiller
|
OL-10-1
|
Automated cloud point analyzer with touch panel control, 1 test position |
|
OL-10-2
|
Automated cloud point analyzer with touch panel control, 2 test positions |
|
OL-14-2
|
Automated analyzers with touch panel control, 1 CFPP & 1 cloud point |
|
OL-40-1
|
Automated analyzer with touch panel control, single test position |
|
OL-40-2
|
Automated analyzer with touch panel control, two test positions |
| Other combinations with Freeze Point and Pour Point are available |
| External Chillers |
|
|
MRCC-80
|
Suitable for up to 3 test positions |
|
MRCC-5
|
Suitable for up to six test positions - 5 Yr compressors guarantee |
|
|
|
DR-CP
|
Test Jar for cloud, mirrored bottom |
|
DR-PP
|
Test Jar for pour point |
|
DR-CF
|
Test Jar for CFPP |
|
DR-FP
|
Test tube for Freeze point |
|
CP-2
|
O-Ring (one per test jar), dozen (Freeze Point test tube does not require o-ring) |
|
CF-11
|
Brass filter assembly (as per ASTM D6371 Fig. 7 & 8). Includes CF-22 |
|
CF-11A
|
Filter disk/screen for CFPP (as per Section 6.1.8.1.c of D6371), dozen |
|
CF-11B
|
Replacement “O” rings for filter screen (large), dozen for CFPP |
|
CF-22
|
Brass Filter Holder with CF-11A filter screen for CFPP |
|
DR-AP
|
Aspiration pipette for CFPP |
|
CF-12A
|
Replacement “O” rings for pipette (small), dozen for CFPP |
|
CF-17
|
Vacuum pump (as per Section 6.1.12) (115 volt) for CFPP |
|
CF-17A
|
Vacuum pump (as per Section 6.1.12) (220 volt) for CFPP |
|
|
Note: Vacuum pump required if suitable vacuum source unavailable. Supports up to 6 positions |
|
DR4-TP
|
Spare sample temperature probe. Suitable for CFPP, pour, and/or freeze point |
|
DR4-TP-Cloud
|
Spare sample temperature probe. Suitable for cloud point (spring loaded) |
|
DR-Kit-CP
|
Recommended spare accessories for automatic Cloud, per position |
|
|
Includes: (6) DR-CP, (1) CP-2 |
|
DR-Kit-PP
|
Recommended spare accessories for automatic Pour, per position |
|
|
Includes: (6) DR-PP, (1) CP-2 |
|
DR-Kit-CF
|
Recommended spare accessories for automatic CFPP, per position |
|
|
Includes: (6) DR-CF, (1) CP-2, (2) CF-11A, (1) CF-11B, (2) DR-AP, (1) CF-12A |
|
|
Note: Vacuum pump, if needed, ordered separately |
|
DR-Kit-FP
|
Recommended spare accessories for automatic Freeze, per position |
|
|
Includes: (6) DR-FP |
|
|
*For other combinations, please inquire.
 |
Automated Cold Filter Plugging Point (CFPP) |
|
|
Specifications are subject to change without notice. |
|
|
|
|
|
 |
|